Before opening
Take the vial out of the freezer and let it reach room temperature while still closed, about 20 minutes. Opening a cold vial condenses water on the powder. Wipe the stopper with 70% isopropanol and let it dry.
Choose the solvent
Most peptides dissolve in HPLC-grade water or buffer. Basic peptides may need 0.1% acetic acid; hydrophobic peptides may need a small volume of DMSO or an HFIP pretreatment. The product page states the recommended solvent. Test with a small fraction of the powder first.
Add the solvent
Inject the solvent down the vial wall, not directly onto the powder. Rotate gently between your palms; do not vortex. Foam and shear promote aggregation. If the powder does not dissolve, check the solvent and pH before adding heat.
Calculate the volume
For a target concentration in mg/mL: volume (mL) = peptide mass (mg) / concentration (mg/mL). Use the peptide content from the COA, not the nominal vial mass. For molarity, use the molecular mass and the content together.
Aliquot and store
Divide the solution into single-use aliquots. Store the powder at -20 °C, protected from light and moisture. Store solutions at -20 °C or -80 °C depending on the product. Avoid repeated freeze-thaw cycles; each cycle damages part of the peptide.
What to write down
- Product, lot and COA date.
- Solvent, volume and concentration.
- Date of preparation and number of aliquots.
- Any change in appearance: turbidity, color, precipitate.
Spanish version: disolver y guardar péptidos.
Research use only. Catalog · COA policy · Contact.