What light does
UV and visible light can oxidize aromatic residues (Trp, Tyr, Phe), break bonds and change conformation. The result is not always visible: a clear solution may have lost peptide or formed aggregates.
Containers
Use amber vials or wrap the tube in aluminum foil. For aliquots, use opaque tubes or a closed box. Do not leave the solution in a clear tube on the bench longer than necessary.
Lighting
Work with indirect light and avoid direct sunlight. Laminar flow cabinets often have UV lamps; do not expose the sample with the lamp on. Turn the UV off when handling the vial.
Time
Photodegradation depends on dose: intensity × time. A short exposure during preparation is not the same as one hour on the bench. Prepare, aliquot and store as quickly as possible.
What to record
Exposure time, light type, container and any color or turbidity change. If the assay is photosensitive, include a protected and an exposed control.