Define the range
Choose a range that covers the expected response and one point below and above. If the range is too narrow, you miss the plateau; if it is too wide, you waste material and time.
Points and replicates
Five to seven points, with at least three replicates per point. Use a geometric scale (1, 3, 10, 30…) if the response is unknown. Include the vehicle at each point or at least one control per plate.
The same handling
All dilutions must use the same solvent, volume and exposure time. If one point carries more DMSO than another, the curve measures the vehicle, not the peptide.
Fit
Plot response against concentration and fit an appropriate model (linear, sigmoid or logarithmic). Do not force a straight line if the response is curved. Report the range, not only the highest point.
What to document
Real concentrations, dilution method, vehicle, number of replicates and fit criterion. The curve is an assay number, not a product property.